Documentation

Specifications

General

MCUESP32-WROOM-32E
Internal power supply(1 to 4) 18650 batteries (lithium-titanate, lithium iron phosphate, lithium-ion, or sodium-ion)
Solar panel5 V or 12 V, 1 W minimum
Communication (cellular)SIMCom SIM7070G (GSM/LTE-M/NB-IoT) or A7670G (GSM/LTE Cat-1)
Communication (satellite)Iridium 9603 or Murata Type 1SC-NTN
Communication (LoRa)Ebyte E220-900T30
Transport protocolUDP with server acknowledgement and retransmission (cellular and NB-NTN), Short Burst Data (Iridium)
Data per transmission90-99 bytes, including IP/UDP headers, depending on number of installed sensors
Storage1 MB on-chip flash memory (approx. 100 days of data)
Recommended transmission interval (cellular)5 minutes
Recommended transmission interval (satellite)1 hour
Recommended measurement interval10 seconds
Programming languageC (main CPU), assembly (ULP), Python (server-side)
Battery life2.6 days per Wh of installed battery capacity (at recommended transmission/measurement intervals, LTE-M w/ PSM)
LicenseGNU General Public License v3.0

Temperature/humidity

Temperature/humidity sensorSensirion SHT45-AD1F
Temperature sensor (low-temperature option)Texas Instruments TMP117
Temperature/humidity measuring method5-minute average or instantaneous
Temperature measurement range (SHT45 only)-40 °F to 140 °F (-40 °C to 60 °C)
Temperature measurement range (SHT45 with TMP117 option)-67 °F to 140 °F (-55 °C to 60 °C)
Temperature accuracy (40 °F to 140 °F)±0.2 °F (0.1 °C)
Temperature accuracy (-67 °F to 40 °F)±0.4 °F (0.2 °C)
Humidity measurement range0% to 100%
Humidity accuracy (20% to 70%)±1%
Humidity accuracy (0% to 20%, 70% to 90%)±1.5%
Humidity accuracy (90% to 100%)±1.8%

Barometric pressure

Barometric pressure sensorBosch BMP580
Barometric pressure measuring methodInstantaneous
Absolute barometric pressure measurement range8.86 inHg to 36.91 inHg (300.0 mbar to 1250.0 mbar)
Barometric pressure accuracy±0.01 inHg (±0.3 mbar)

Precipitation

Rain gauge typeTipping bucket
Rain gauge hall switchCross Chip CC6201
Precipitation rate measuring methodInstantaneous
Daily precipitation accumulation measurement range0.00 in to 80.00 in (0.0 mm to 2032.0 mm)
Precipitation accumulation accuracy±1% or ±0.01 in (0.3 mm), whichever is greater
Precipitation rate measurement range0.00 in/h to 10.00 in/h (0.0 mm/h to 254.0 mm/h)
Precipitation rate accuracy±10%

Wind

Anemometer typeMechanical, three-cup
Wind direction sensorAMS AS5600
Wind speed hall switchHuaxin HX6286
Wind speed measuring method2-minute average
Wind speed measurement range0.0 mph to 400.0 mph (0.0 km/h to 643.7 km/h)

Solar irradiance

Pyranometer typePhotovoltaic
Solar cellANYSOLAR KXOB25-04X1TF
Current sensorTexas Instruments INA226
Solar irradiance measuring method5-minute average or instantaneous
Solar irradiance measurement range0 W/m² to 2000 W/m²

Design criteria

Power supply

The station must be able to be powered by the following battery types:

Battery typeNominal voltageMaximum voltageMinimum voltage
Lithium-ion (NMC, NCA)3.7 V4.2 V2.5 V
Lithium iron phosphate (LFP)3.2 V3.6 V2.5 V
Lithium-titanate (LTO)2.3 V2.8 V1.6 V
Sodium-ion3.0 V4.1 V1.6 V

The power supply must be able to provide 2.0 A at 4.0 V to the communication module throughout its entire voltage range, as well as 500 mA at 3.3 V to the MCU. Pass-through operation for communication module input voltages higher than 4.0 V is acceptable up to 4.2 V, the maximum voltage of the lithium-ion battery.

The battery must be protected from undervoltage by disabling the power supply to the MCU at its minimum voltage. During shutdown (in either the undervoltage or power-off state), the current consumption must not exceed 50 μA. The appropriate undervoltage threshold for the installed battery type should be jumper-selectable.

The station should include capacity for up to four (4) parallel 18650 cells, as well as a connector for an external battery for additional capacity in low-light environments or higher-power applications.

Solar panel and charger

The station should support both 5 V and 12 V solar panels. Due to the lack of a charger IC that supports both voltages, the charger must be designed as a separate module which can be easily changed to suit the installed solar panel. The relevant charger ICs are described in the following table:

Charger ICTopologyInput voltage rangeBattery typeMaximum charge current
CN3795Switch-mode6.6 V to 30 VAll4 A
CN3156Linear3.2 V to 6.0 VLithium-titanate950 mA
CN3158Linear4.4 V to 6.0 VLithium iron phosphate1 A
CN3163Linear4.4 V to 6.0 VLithium-ion1 A

The linear chargers are suitable only for their specific battery type and have lower efficiencies than switch-mode chargers, but require fewer external components.

Bill of materials

Electrical design

Schematics

Main PCB

Battery Charger

Temperature/Humidity Sensor

Pyranometer

PCB files

Main PCB (version 2.1)

Temperature/Humidity Sensor (SHT45)

Photos

Mechanical design

Drawing files

STEP files

DXF files

Images

Firmware