Specifications
General
| MCU | ESP32-WROOM-32E |
| Internal power supply | (1 to 4) 18650 batteries (lithium-titanate, lithium iron phosphate, lithium-ion, or sodium-ion) |
| Solar panel | 5 V or 12 V, 1 W minimum |
| Communication (cellular) | SIMCom SIM7070G (GSM/LTE-M/NB-IoT) or A7670G (GSM/LTE Cat-1) |
| Communication (satellite) | Iridium 9603 or Murata Type 1SC-NTN |
| Communication (LoRa) | Ebyte E220-900T30 |
| Transport protocol | UDP with server acknowledgement and retransmission (cellular and NB-NTN), Short Burst Data (Iridium) |
| Data per transmission | 90-99 bytes, including IP/UDP headers, depending on number of installed sensors |
| Storage | 1 MB on-chip flash memory (approx. 100 days of data) |
| Recommended transmission interval (cellular) | 5 minutes |
| Recommended transmission interval (satellite) | 1 hour |
| Recommended measurement interval | 10 seconds |
| Programming language | C (main CPU), assembly (ULP), Python (server-side) |
| Battery life | 2.6 days per Wh of installed battery capacity (at recommended transmission/measurement intervals, LTE-M w/ PSM) |
| License | GNU General Public License v3.0 |
Temperature/humidity
| Temperature/humidity sensor | Sensirion SHT45-AD1F |
| Temperature sensor (low-temperature option) | Texas Instruments TMP117 |
| Temperature/humidity measuring method | 5-minute average or instantaneous |
| Temperature measurement range (SHT45 only) | -40 °F to 140 °F (-40 °C to 60 °C) |
| Temperature measurement range (SHT45 with TMP117 option) | -67 °F to 140 °F (-55 °C to 60 °C) |
| Temperature accuracy (40 °F to 140 °F) | ±0.2 °F (0.1 °C) |
| Temperature accuracy (-67 °F to 40 °F) | ±0.4 °F (0.2 °C) |
| Humidity measurement range | 0% to 100% |
| Humidity accuracy (20% to 70%) | ±1% |
| Humidity accuracy (0% to 20%, 70% to 90%) | ±1.5% |
| Humidity accuracy (90% to 100%) | ±1.8% |
Barometric pressure
| Barometric pressure sensor | Bosch BMP580 |
| Barometric pressure measuring method | Instantaneous |
| Absolute barometric pressure measurement range | 8.86 inHg to 36.91 inHg (300.0 mbar to 1250.0 mbar) |
| Barometric pressure accuracy | ±0.01 inHg (±0.3 mbar) |
Precipitation
| Rain gauge type | Tipping bucket |
| Rain gauge hall switch | Cross Chip CC6201 |
| Precipitation rate measuring method | Instantaneous |
| Daily precipitation accumulation measurement range | 0.00 in to 80.00 in (0.0 mm to 2032.0 mm) |
| Precipitation accumulation accuracy | ±1% or ±0.01 in (0.3 mm), whichever is greater |
| Precipitation rate measurement range | 0.00 in/h to 10.00 in/h (0.0 mm/h to 254.0 mm/h) |
| Precipitation rate accuracy | ±10% |
Wind
| Anemometer type | Mechanical, three-cup |
| Wind direction sensor | AMS AS5600 |
| Wind speed hall switch | Huaxin HX6286 |
| Wind speed measuring method | 2-minute average |
| Wind speed measurement range | 0.0 mph to 400.0 mph (0.0 km/h to 643.7 km/h) |
Solar irradiance
| Pyranometer type | Photovoltaic |
| Solar cell | ANYSOLAR KXOB25-04X1TF |
| Current sensor | Texas Instruments INA226 |
| Solar irradiance measuring method | 5-minute average or instantaneous |
| Solar irradiance measurement range | 0 W/m² to 2000 W/m² |
Design criteria
Power supply
The station must be able to be powered by the following battery types:
| Battery type | Nominal voltage | Maximum voltage | Minimum voltage |
| Lithium-ion (NMC, NCA) | 3.7 V | 4.2 V | 2.5 V |
| Lithium iron phosphate (LFP) | 3.2 V | 3.6 V | 2.5 V |
| Lithium-titanate (LTO) | 2.3 V | 2.8 V | 1.6 V |
| Sodium-ion | 3.0 V | 4.1 V | 1.6 V |
The power supply must be able to provide 2.0 A at 4.0 V to the communication module throughout its entire voltage range, as well as 500 mA at 3.3 V to the MCU.
Pass-through operation for communication module input voltages higher than 4.0 V is acceptable up to 4.2 V, the maximum voltage of the lithium-ion battery.
The battery must be protected from undervoltage by disabling the power supply to the MCU at its minimum voltage. During shutdown (in either the undervoltage or power-off state),
the current consumption must not exceed 50 μA. The appropriate undervoltage threshold for the installed battery type should be jumper-selectable.
The station should include capacity for up to four (4) parallel 18650 cells, as well as a connector for an external battery for additional capacity in low-light environments or higher-power applications.
Solar panel and charger
The station should support both 5 V and 12 V solar panels. Due to the lack of a charger IC that supports both voltages, the charger must be designed as a separate module which can be easily changed
to suit the installed solar panel. The relevant charger ICs are described in the following table:
| Charger IC | Topology | Input voltage range | Battery type | Maximum charge current |
| CN3795 | Switch-mode | 6.6 V to 30 V | All | 4 A |
| CN3156 | Linear | 3.2 V to 6.0 V | Lithium-titanate | 950 mA |
| CN3158 | Linear | 4.4 V to 6.0 V | Lithium iron phosphate | 1 A |
| CN3163 | Linear | 4.4 V to 6.0 V | Lithium-ion | 1 A |
The linear chargers are suitable only for their specific battery type and have lower efficiencies than switch-mode chargers, but require fewer external components.
Bill of materials
Electrical design
Schematics
Main PCB
- Version 2.1
- U1 changed from TLV4041R1 to MIC842HYC5. SC-70 package eliminates need for x-ray inspection.
- R5, R15 changed from 91K to 90.9K due to availability.
- P1 manufacturer changed from XUNPU to UMAX due to availability.
- Version 2.0
Battery Charger
Temperature/Humidity Sensor
- SHT45 (temperature/humidity measurement to -40 °F)
- SHT45 and TMP117 (temperature/humidity measurement to -40 °F; temperature-only measurement to -67 °F)
Pyranometer
PCB files
Main PCB (version 2.1)
Temperature/Humidity Sensor (SHT45)
Photos
Mechanical design
Drawing files
STEP files
DXF files
Images
Firmware